{"id":911,"date":"2018-03-21T05:01:13","date_gmt":"2018-03-21T05:01:13","guid":{"rendered":"https:\/\/www.rhfs.com\/pulse\/?p=911"},"modified":"2025-04-08T14:38:31","modified_gmt":"2025-04-08T14:38:31","slug":"plast-o-matic-pds-pulsation-dampeners-prevent-pipe-valve-pump-and-instrumentation-damage","status":"publish","type":"post","link":"https:\/\/www.rhfs.com\/pulse\/plast-o-matic-pds-pulsation-dampeners-prevent-pipe-valve-pump-and-instrumentation-damage\/","title":{"rendered":"Pulsation Dampeners Prevent Costly Damage"},"content":{"rendered":"<p><a href=\"https:\/\/www.rhfs.com\/root.html?filter=brand%3A2%3ASeries%20PDS#cds-product-container\">Plast-O-Matic Series PDS Pulsation Dampeners<\/a> are a robust solution for combating the damaging effect of water hammer and pulsation. Water hammer and\/or unwanted pulsation can cause serious problems and failures in any piping system, leading to costly&nbsp;downtime while repairs are made to piping system components, gauges, pumps and instrumentation. These failures will continue until the root cause is addressed and remedied.<\/p>\n<p><!--more--><\/p>\n<div id=\"attachment_903\" style=\"width: 280px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2018\/03\/Water-Hammer-photo-3.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-903\" class=\"size-full wp-image-903\" src=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2018\/03\/Water-Hammer-photo-3.jpg\" alt=\"Plast-O-Matic Pulsation Dampeners\" width=\"270\" height=\"270\" srcset=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2018\/03\/Water-Hammer-photo-3.jpg 270w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2018\/03\/Water-Hammer-photo-3-150x150.jpg 150w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2018\/03\/Water-Hammer-photo-3-90x90.jpg 90w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2018\/03\/Water-Hammer-photo-3-75x75.jpg 75w\" sizes=\"auto, (max-width: 270px) 100vw, 270px\" \/><\/a><p id=\"caption-attachment-903\" class=\"wp-caption-text\">Plast-O-Matic pulsation dampeners, Series PDS<\/p><\/div>\n<h5>How the&nbsp;Series PDS Works:<\/h5>\n<p>Pulsation Dampeners and Surge Suppressors will steady a pulsing flow caused by diaphragm pumps, piston pumps, peristaltic pumps and other quick flow interrupting equipment. When used properly, quick pulsating flows will be greatly reduced preventing a number of flow control problems. Pulsation dampening provides the added benefit of smoothing the output supplied by many types of pumps, especially double diaphragm pumps. The PDS will steady a vibrating pointer of a pressure gauge or flow meter under flowing conditions. This provides a steady, uninterrupted supply to points of use, which will greatly enhance system productivity, prolong pump life, and prevent splashing and foaming.<\/p>\n<p>When used properly as an Arrestor, water hammer will be greatly reduced and prevent pipe vibration and leaking connections, damage to valves and filters, ruptured tanks and other equipment damage.<\/p>\n<p>Series PDS&nbsp;dampeners are available in three capacities\/sizes: <strong>10 cubic inch&nbsp;capacity<\/strong> with a 1&#8243; NPT process connection, <strong>50 cubic inch capacity<\/strong> with a 2&#8243; NPT process connection, and <strong>180 cubic inch capacity<\/strong> with a 3&#8243; NPT process connection. Body materials are a choice of <strong><a href=\"https:\/\/www.rhfs.com\/manufacturer.html?page=search&amp;cid=chemical-metering-pumps&amp;filter=brand:2:Series%20PDS;material:2:PVC#cds-products-container\">Geon PVC<\/a><\/strong>, <strong><a href=\"https:\/\/www.rhfs.com\/manufacturer.html?page=search&amp;cid=chemical-metering-pumps&amp;filter=brand:2:Series%20PDS;material:2:CPVC#cds-products-container\">CPVC<\/a><\/strong>, <strong><a href=\"https:\/\/www.rhfs.com\/manufacturer.html?page=search&amp;cid=chemical-metering-pumps&amp;filter=brand:2:Series%20PDS;material:2:Polypro#cds-products-container\">Natural Polypropylene<\/a><\/strong>, or <strong><a href=\"https:\/\/www.rhfs.com\/manufacturer.html?page=search&amp;cid=chemical-metering-pumps&amp;filter=brand:2:Series%20PDS;material:2:PVDF#cds-products-container\">Kynar PVDF<\/a><\/strong>. Inlet screen and dome top match the selected body material. Bladder material is EPDM or FKM. Air inlet valve and gauge isolation valve (non-wetted) are brass. Fasteners are stainless steel.<\/p>\n<p>For other material or connection requirements, please contact <a href=\"https:\/\/www.rhfs.com\/contact.html\">RHFS Customer Service<\/a> at 800-848-1141.<\/p>\n<h5><\/h5>\n<h5>Versatile Dampeners&nbsp;with Many Benefits<\/h5>\n<p>Series PDS Pulsation Dampeners provide six important functions:<\/p>\n<ul>\n<li>As a Dampener, they smooth pump flow<\/li>\n<li>As a Surge Suppressor, they absorb shocks and vibrations<\/li>\n<li>As a Water Hammer Arrestor, they eliminate dangerous pressure spikes caused by quick closing valves<\/li>\n<li>As an Inlet Stabilizer, they enhance pump performance and longevity<\/li>\n<li>As an Accumulator, they release stored fluid during unwanted pressure drops<\/li>\n<li>As an Expansion Tank, they protect systems from thermal volume increases<\/li>\n<\/ul>\n<p>Series PDS Pulsation Dampeners also feature the following important design features:<\/p>\n<ul>\n<li>A large inlet to improve response<\/li>\n<li>Inlet screen to protect bladder with minimal flow obstruction<\/li>\n<li>Dual seal channels to protect against air and system leaks<\/li>\n<li>Top quality thermoplastics and elastomers resist chemical attack and protect system purity<\/li>\n<li>No wetted metal parts<\/li>\n<li>Up to 150 PSI working pressure (excluding pressure spikes)<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.rhfs.com\/contact.html\">Contact Ryan Herco Flow Solutions<\/a> today and we can help you select and size a Plast-O-Matic Series PDS Pulsation Dampener for your application.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"padding-left: 30px;\">Link:&nbsp;<a href=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2018\/03\/Pulsation-Dampener-Data-Sheet.pdf\">Series PDS Pulsation Dampener Data Sheet<\/a><\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background\" href=\"https:\/\/www.rhfs.com\/products.html\" style=\"background-color:#161e68\">View Our Products<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background\" href=\"https:\/\/www.rhfs.com\/manufacturer-listing.html\" style=\"background-color:#161e68\">View Manufacturers<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Plast-O-Matic Series PDS Pulsation Dampeners are a robust solution for combating the damaging effect of water hammer and pulsation. Water hammer and\/or unwanted pulsation can cause serious problems and failures in any piping system, leading to costly&nbsp;downtime while repairs are made to piping system components, gauges, pumps and instrumentation. These failures will continue until the root cause is addressed and [&#8230;]<\/p>\n","protected":false},"author":5,"featured_media":932,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[30],"tags":[129,131,130,133],"class_list":["post-911","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pumping-systems","tag-plastomatic","tag-pulsation","tag-pulsation-dampener","tag-series-pds"],"_links":{"self":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts\/911","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/comments?post=911"}],"version-history":[{"count":15,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts\/911\/revisions"}],"predecessor-version":[{"id":2463,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts\/911\/revisions\/2463"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/media\/932"}],"wp:attachment":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/media?parent=911"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/categories?post=911"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/tags?post=911"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}