{"id":1419,"date":"2020-07-09T00:12:00","date_gmt":"2020-07-09T00:12:00","guid":{"rendered":"https:\/\/www.rhfs.com\/pulse\/?p=1419"},"modified":"2025-04-08T14:28:01","modified_gmt":"2025-04-08T14:28:01","slug":"gf-signet-9950-smartpro-dual-channel-transmitter","status":"publish","type":"post","link":"https:\/\/www.rhfs.com\/pulse\/gf-signet-9950-smartpro-dual-channel-transmitter\/","title":{"rendered":"+GF+ Signet 9950 SmartPro Dual Channel Transmitter"},"content":{"rendered":"<h5><strong><br>The 9950 SmartPro\u00ae is Packed with Features<\/strong><\/h5>\n<p>The <a href=\"https:\/\/www.rhfs.com\/root.html?cdskeys=Georg%20Fischer%20Signet%209950#cds-product-container#cds-attribute-type\">SmartPro 9950<\/a> is a two channel controller that supports two sensors of the same or different types in one instrument. With an advanced feature set, the 9950 provides flexibility at an affordable price point.<\/p>\n<p><!--more--><\/p>\n<h5><strong><a href=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter01.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-1421\" src=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter01-300x297.png\" alt=\"\" width=\"300\" height=\"297\" srcset=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter01-300x297.png 300w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter01-150x150.png 150w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter01-90x90.png 90w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter01-75x75.png 75w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter01.png 451w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/strong><\/h5>\n<p>The sensor types supported by the 9950 are Signet <a href=\"https:\/\/www.rhfs.com\/flow-meters-flow-sensors.html?filter=manufacturer%3A2%3AGeorg%20Fischer%20Signet%3Btype%3A2%3AFlow%3Bbrand%3A2%3ARotor-X%3AMetalex%3AMini-Flo%3AMicro-Flow#cds-product-container#cds-attribute-brand\">Flow<\/a>, <a href=\"https:\/\/www.rhfs.com\/ph-orp.html?filter=manufacturer%3A2%3AGeorg%20Fischer%20Signet%3Btype%3A2%3ApH%20%2F%20ORP%3ApH%3AORP%3Bbrand%3A2%3ADryLoc#cds-product-container#cds-attribute-brand\">pH\/ORP<\/a>, <a href=\"https:\/\/www.rhfs.com\/conductivity-resistivity.html?filter=manufacturer%3A2%3AGeorg%20Fischer%20Signet&amp;cdskeys=sensor#cds-product-container\">Conductivity\/Resistivity<\/a>, Salinity, <a href=\"https:\/\/www.rhfs.com\/pressure-temperature.html?filter=manufacturer%3A2%3AGeorg%20Fischer%20Signet%3Btype%3A2%3ATemperature&amp;cdskeys=sensor#cds-product-container#cds-attribute-type\">Temperature<\/a>, <a href=\"https:\/\/www.rhfs.com\/pressure-temperature.html?filter=manufacturer%3A2%3AGeorg%20Fischer%20Signet%3Btype%3A2%3APressure&amp;cdskeys=sensor#cds-product-container#cds-attribute-type\">Pressure<\/a>, <a href=\"https:\/\/www.rhfs.com\/liquid-level-control.html?filter=manufacturer%3A2%3AGeorg%20Fischer%20Signet%3Btype%3A2%3ALevel#cds-product-container#cds-attribute-type\">Level<\/a>, <a href=\"https:\/\/www.rhfs.com\/specialty-systems.html?filter=manufacturer%3A2%3AGeorg%20Fischer%20Signet%3Btype%3A2%3ADissolved%20Oxygen#cds-product-container#cds-attribute-type\">Dissolved Oxygen<\/a>, and devices that transmit a 4 to 20 mA signal with the use of the 8058 iGo\u00ae Signal Converter.<\/p>\n<p>Simplified monitoring made even better with these new (Gen 3) features:<\/p>\n<ul>\n<li>Conductivity Module for monitoring two different readings<\/li>\n<li>Modbus Module for easy connections to existing networks<\/li>\n<li>Automatic measurement of pH glass impedance<\/li>\n<li>Selectable parameters for broken glass detection<\/li>\n<\/ul>\n<p>The 9950 includes advanced features such as derived functions, advanced multiple relay modes, and timer based relay functions. Derived functions allows for the control of a relay or current loop with the sum, delta (difference), or ratio of two measurements, for example delta pressure and delta temperature. Multiple relay modes allow up to three signals to be used for the control of a single relay. This can be any combination of analog and binary inputs.&nbsp; The timer relay modes allow a relay to be activated on a repeating basis from every minute to once every 30 days. Weekday timer mode allows a relay to be energized on a specific day or days of the week at a specific time.<\/p>\n<p><strong><a href=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter_a.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1428 size-medium alignright\" src=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter_a-300x272.png\" alt=\"\" width=\"300\" height=\"272\" srcset=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter_a-300x272.png 300w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter_a.png 496w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/strong>Applications for the SmartPro 9950 Dual Channel Transmitter include:<\/p>\n<ul>\n<li>Wastewater Treatment<\/li>\n<li>Reverse Osmosis<\/li>\n<li>Deionization<\/li>\n<li>Chemical Manufacturing\/Addition<\/li>\n<li>Metal and Plastic Finishing<\/li>\n<li>Fume Scrubbers<\/li>\n<li>Cooling Towers<\/li>\n<li>Media Filtration<\/li>\n<li>Chemical Dosing\/Injection<\/li>\n<li>Aquatic Life Support<\/li>\n<li>Pools &amp; Fountains<\/li>\n<li>Rinse Tanks<\/li>\n<li>Chemical Neutralization<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-1431 size-medium\" src=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter02-a-300x223.png\" alt=\"\" width=\"300\" height=\"223\" srcset=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter02-a-300x223.png 300w, https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2019\/10\/GF-Transmitter02-a.png 496w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<h5><strong>Advantages:<\/strong><\/h5>\n<ul>\n<li>Automatic pH glass impedance measurement<\/li>\n<li>Selectable parameters for broken glass detection<\/li>\n<li>Reads stored data in all Signet DryLoc\u00ae pH\/ORP electrodes<\/li>\n<li>One instrument for multiple sensor types<\/li>\n<li>Two different sensor types can be combined in one instrument<\/li>\n<li>Configurable display<\/li>\n<li>Derived measurements<\/li>\n<li>Advanced boolean logic<\/li>\n<li>Optional modules can be added for additional capabilities<\/li>\n<li>USB port for field upgrades using standard USB flash drives<\/li>\n<\/ul>\n<p><span style=\"font-family: Calibri;\"><strong><span style=\"color: #000000;\"><a href=\"https:\/\/www.youtube.com\/watch?v=AxPTccD5btM\">For more information, check out this quick video!<\/a><\/span><\/strong><u><\/u><\/span><\/p>\n<p>You can also contact Ryan Herco Flow Solutions at 800.848.1141 or by <a href=\"https:\/\/www.rhfs.com\/contact.html\">clicking here<\/a> to learn more about the Signet 9950 SmartPro Dual Channel Transmitter.<\/p>\n<p><\/p>\n<h5>Downloads:<\/h5>\n<ul>\n<li><a href=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2020\/07\/Signet-9950-Product-Brochure.pdf\">Signet 9950 SmartPro Brochure<\/a><\/li>\n<li><a href=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2020\/07\/Signet-9950-Transmitter-Datasheet.pdf\">Signet 9950 SmartPro Datasheet<\/a><\/li>\n<li><a href=\"https:\/\/www.rhfs.com\/pulse\/wp-content\/uploads\/2020\/07\/9950-Transmitter-Manual-English.pdf\">Signet 9950 SmartPro Manual<\/a><\/li>\n<\/ul>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background\" href=\"https:\/\/www.rhfs.com\/products.html\" style=\"background-color:#161e68\">View Our Products<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background\" href=\"https:\/\/www.rhfs.com\/manufacturer-listing.html\" style=\"background-color:#161e68\">View Manufacturers<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The 9950 SmartPro\u00ae is Packed with Features The SmartPro 9950 is a two channel controller that supports two sensors of the same or different types in one instrument. With an advanced feature set, the 9950 provides flexibility at an affordable price point.<\/p>\n","protected":false},"author":16,"featured_media":1643,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[28],"tags":[53,161,162,84],"class_list":["post-1419","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-instrumentation","tag-georg-fischer","tag-signet-9950","tag-smartpro","tag-transmitter"],"_links":{"self":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts\/1419","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/comments?post=1419"}],"version-history":[{"count":27,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts\/1419\/revisions"}],"predecessor-version":[{"id":2446,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/posts\/1419\/revisions\/2446"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/media\/1643"}],"wp:attachment":[{"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/media?parent=1419"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/categories?post=1419"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rhfs.com\/pulse\/wp-json\/wp\/v2\/tags?post=1419"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}